(630)365-5527
|
Drum
Washer DW55 300 Horizontal
|
Specifications for the System Operation
Controls |
|
Operation |
Timer / Relay / PLC Controls |
|
Electrical Power Requirements for the System |
55 Amps at 480 Volt. 3 Phase, 60 Hz.
6 Gage supply wire |
|
Control Box Rating |
Nema 4 |
|
System Controls |
110 Volt. 1 phase 60 Hz. |
|
Push Buttons |
Intrinsically Safe 24 Volt DC |
|
Total Cycle Time |
Operator Selectable with timer |
|
Operator Controls Location |
On the drum wash stand |
|
Specifications for the Drum Wash Basin |
|
Wash Basin Construction |
304 Stainless Steel |
|
Wash Basin Stand Construction |
Carbon Steel Galvanized |
|
Safety Switch |
24 Volt DC |
|
Wash Head |
Rotating nozzle (Stainless steel/Bronze)
Standard |
|
Container Size |
Drums sized up to 55 gal (208.14 l) |
|
Portability |
No this unit is stationary |
|
Wash Basin Sump Capacity |
120 Gallons (454.12 l) |
|
Drum Wash Basin Dimensions |
| |
Unit Height |
91.5” (232.41 cm) |
| |
Unit Width |
46.5” (118.11 cm) |
| |
Unit Length |
60” (152.40 cm) |
| |
Unit Weight |
800 lbs. (362.87 kg) |
|
Specifications Recirculation System |
|
Construction of the Tank |
12 Gage 304 Stainless Steel |
|
Construction of the Stand |
Galvanized Steel |
|
Capacity gallons |
250 Gal. (946.07 l) |
|
Tank Type |
Rectangular |
|
Fluid Return Chamber |
100 Gallons (378.43 l) |
|
Portability |
No this unit is stationary |
|
Wash Pumps and Wash Pump Motor |
10 HP Electric 480 Volt. 3 phase 60 Hz. 350
PSI, 30 GPM |
|
Return Pump and Return Pump Motor |
5 HP 480 Volt 3 phase 60 hz 25 gpm 150 PSI |
|
Tank and Pump Stand Dimensions: |
|
| |
Unit Height |
57.2” (145.28 cm) |
| |
Unit Depth |
43” (190.22 cm) |
| |
Unit Width |
182.3” (463.04 cm) |
|
|
Unit Weight |
2000 lbs. (1 ton) |
|
Non Explosion Proof Equipment Options: |
|
Option A: |
Two (02) Immersion Heaters for the
recirculation system with electrical system at 480 V, 3 phase
60 hertz. 20,000 Watts (10,000 Watts each). Note: If heat is
required, it is recommended that the entire system be operated
at 480 volt to reduce the amount of amps used. Other voltages
and hertz are available on upon request. This option includes
tank insulation |
|
Option B: |
Oil Recovery Skimmer System for the
recirculation system. Ex Works Elburn, IL (The Oil Skimmer
System will eliminate the need to remove the accumulated oils
and grease that will be on the top of the cleaning solution) |
|
Option C: |
Auto Flocculation for dispensing powder
flock |
|
Option D: |
Complete caustic and acid plumbing package.
This plumbing package is required when cleaning drums with any
caustic and/or acid wash solutions. |
|
Option E: |
High Impact Nozzle. 316 stainless steel.
Flow range is 3 to 6 gpm (11 to 23 lpm). This is a fluid
driven wash nozzle that will cover 100% of the interior of the
drum surface. |
|
Option F: |
Floculation and Mixing System. This option
includes a 1 hp motor with a freguency drive, 10” aluminum
mixer, 304 Stainless Steel Media Basket and 15 Cubic Feet of
Filter Media |
|
Explosion Proof Options: |
|
Option A: |
Air Purge Explosion Resistant Nema
4. This option is used instead of explosion proof enclosure
rated for Nema 7/9. The air purge explosion resistant
enclosure is an enclosure pressurized and purged that operates
on a supply of compressed instrument air or inert gas. The
enclosure pressure is monitored and regulated to prevent
flammable gas or vapor accumulation or combustible dust
accumulation. All other electrical components are rated for
Class I Div I Groups C&D. |
|
Option B: |
Explosion Proof System
Class I Div I Group C&D. The motor
starter/disconnect box is a cast aluminum corrosion resistant
Nema 7/9 enclosure with Nema 4 seals. The motor, float
switches, sensors, push buttons and valves would all be rated
for this classification. |
|
Option C: |
Two (02) Immersion Heaters for the
recirculation tank with electrical system at 480 V, 3 phase 60
hertz. 20,000 Watts (10,000 Watts each). Note: If heat is
required, it is recommended that the entire system be operated
at 480 volt to reduce the amount of amps used. Other voltages
and hertz are available on upon request. This option includes
tank insulation Class I Div I Group C&D |
|
Option D: |
Oil Recovery Skimmer System for the
recirculation system. Ex Works Elburn, IL (The Oil Skimmer
System will eliminate the need to remove the accumulated oils
and grease that will be on the top of the cleaning solution) Class
I Div I Group C&D |
|
Option E:
|
Floculation and Mixing System. This option
includes a 1 hp motor with a freguency drive, 10” aluminum
mixer, 304 Stainless Steel Media Basket and 15 Cubic Feet of
Filter Media all rated for Class I Div I Group C&D |
<<back |
|